<?xml version="1.0" encoding="utf-8"?>
<?xml-stylesheet href="http://blogs.albawaba.com/styles/rss.css" type="text/css"?>
<rss version="2.0" 
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
>
 <channel>
  <title>Oil Regeneration</title>
  <link>http://blogs.albawaba.com/ukrbudmash</link>
  <description></description>
  <pubDate>Sat, 27 Dec 2008 10:13:49 +0000</pubDate>
  <generator>http://blogs.albawaba.com</generator>
    <item>
   <title>Hydraulic Press DB 2240 2240</title>
   <description>
    &lt;span&gt;UkrBudMash Ltd. sells Hydraulic Press DB 2240 (second-hand, but completely in an excellent working condition).&lt;br /&gt; &lt;/span&gt;&lt;a id=&quot;res_7682&quot; href=&quot;/resserver.php?blogId=66498&amp;amp;resource=hydraulic%20press.jpg&quot;&gt;&lt;img src=&quot;/resserver.php?blogId=66498&amp;amp;resource=hydraulic%20press.jpg&amp;amp;mode=preview&quot; border=&quot;0&quot; /&gt;&lt;/a&gt;&lt;br /&gt;&lt;span&gt; Hydraulic Press DB 2240 characteristics:&lt;br /&gt; &lt;br /&gt; - Purpose: The Hydraulic Press is intended for pressing large-size products.&lt;br /&gt; - Capacity of press, 1000 tons on sq. cm;&lt;br /&gt; - Lift cylinder capacity, 200 tons on sq. cm;&lt;br /&gt; - Center pusher capacity on combustion stroke 160 tons on sq. cm; on backward stroke 80 tons on sq. cm;&lt;br /&gt; - Back pusher capacity on combustion stroke 25 tons on sq. cm; on backward stroke 20 tons on sq. cm;&lt;br /&gt; - Stage movement cylinder capacity 27 tons on sq. cm;&lt;br /&gt; - Hydraulic fluid nominal pressure 320 kg on sq.cm.&lt;br /&gt; - Walking beam move - 1000 mm.&lt;br /&gt; - The established capacity of electric motors, kw 40,5.&lt;br /&gt; &lt;br /&gt; The Hydraulic Press Dimensions:&lt;br /&gt; &lt;br /&gt; Length 6400&lt;br /&gt; Width 5030&lt;br /&gt; Height 9800&lt;br /&gt; - Height press above a level of a floor, mm 6500&lt;br /&gt; - Weight press, kg 69800&lt;br /&gt; &lt;br /&gt; Only 100.000 USD.&lt;/span&gt;
   </description>
   <link>http://blogs.albawaba.com/ukrbudmash/68207/2008/09/26/100496-hydraulic-press-db-2240-2240</link>
   <comments>http://blogs.albawaba.com/ukrbudmash/68207/2008/09/26/100496-hydraulic-press-db-2240-2240</comments>
   <guid>http://blogs.albawaba.com/ukrbudmash/68207/2008/09/26/100496-hydraulic-press-db-2240-2240</guid>
      <dc:creator>ukrbudmash</dc:creator>
      
    <category>General</category>
         <pubDate>Fri, 26 Sep 2008 11:11:10 +0000</pubDate>
   <source url="http://blogs.albawaba.com/feed/rss20/66498">Oil Regeneration</source>
                    </item>
    <item>
   <title>Oil Regeneration Station type URM - 0,5</title>
   <description>
    &lt;p class=&quot;MsoNormal&quot; style=&quot;margin-bottom: 12pt&quot;&gt;&lt;a id=&quot;res_7612&quot; href=&quot;/resserver.php?blogId=66498&amp;amp;resource=7612-urm.jpg&quot;&gt;&lt;img src=&quot;/resserver.php?blogId=66498&amp;amp;resource=7612-urm.jpg&amp;amp;mode=preview&quot; border=&quot;0&quot; /&gt;&lt;/a&gt;Regeneration of transformer oils is needed when the transformer oil has
deteriorated to a level whereby regular oil purification (cleaning
&amp;amp; filtration) is no longer adequate. The regeneration or
reclamation process requires passing the deteriorated transformer oil
through an adsorbent media such as specifically prepared (know-how)
sorbent powder.&lt;br /&gt;
&lt;br /&gt;
Sorbent powder&amp;rsquo;s consumption in URM-0,5 is ranged between 4% and 6%
of the weight of regenerated oil. One-pass clay load is 50 kg, which
enables regeneration of 1 ton of oil.&lt;br /&gt;
&lt;br /&gt;
The URM-0,5 system includes oil heater, coarse filter, fine filter, and
oil pump are assembled together in a single unit (Fig.1). A
press-filter, the separate unit (Fig. 2), holds sorbent powder for
final processing of oil&lt;br /&gt;
that has passed the main unit. &lt;span&gt;&lt;/span&gt;&lt;/p&gt;
   </description>
   <link>http://blogs.albawaba.com/ukrbudmash/68207/2008/07/25/91812-oil-regeneration-station-type-urm-0-5</link>
   <comments>http://blogs.albawaba.com/ukrbudmash/68207/2008/07/25/91812-oil-regeneration-station-type-urm-0-5</comments>
   <guid>http://blogs.albawaba.com/ukrbudmash/68207/2008/07/25/91812-oil-regeneration-station-type-urm-0-5</guid>
      <dc:creator>ukrbudmash</dc:creator>
      
    <category>General</category>
         <pubDate>Fri, 25 Jul 2008 10:56:53 +0000</pubDate>
   <source url="http://blogs.albawaba.com/feed/rss20/66498">Oil Regeneration</source>
                    </item>
    <item>
   <title>Oil Regeneration Station type URM - 0,8</title>
   <description>
    &lt;p class=&quot;MsoNormal&quot; style=&quot;margin-bottom: 12pt&quot;&gt;&lt;a id=&quot;res_7683&quot; href=&quot;/resserver.php?blogId=66498&amp;amp;resource=7683-oil%20regeneration.jpg&quot;&gt;&lt;img src=&quot;/resserver.php?blogId=66498&amp;amp;resource=7683-oil%20regeneration.jpg&amp;amp;mode=preview&quot; border=&quot;0&quot; /&gt;&lt;/a&gt;&lt;a id=&quot;res_7613&quot; href=&quot;/resserver.php?blogId=66498&amp;amp;resource=7613-urm.jpg&quot;&gt;&lt;span&gt;Oil Regeneration &amp;amp;
reclamation systems for industrial lubrication oils. Transformer Oil
Regeneration Station type (R) 0,8 is apply to purify and regenerate the
used insulating oils such as power transformer oil, high-voltage switch
oil, mutual inductor oil whose viscosity at temperature 50 C does not
exceed 70 cSt. It removes water, gas, particulate matters, free carbon,
deep oxides. It also removes acidity and vaccuumizes a transformer. The
Station can recover the oil color. After purification, the used
insulating oil can reach international standard and recover its
original function. Oil Regeneration Station is used for mounting,
repairing and operating high-voltage oil equipment with voltage up to
1150 kV (power transformers, high-voltage switches, mutual inductors,
cable and capacitors which have insulation system). The machine
complies with number 4 category placement and climatic design UHL as
per GOST 15 150-69. Capacity, m3/h 0,7 Sorbent consumption, % by oil
weight 4-6 One-time sorbent feeding, kg 50 Oil temperature, 95 Oil
heater power, W 27 Set power consumption, W 37 Three-phase VAC~ 50 Hz,
V 380.&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
   </description>
   <link>http://blogs.albawaba.com/ukrbudmash/68207/2008/07/25/91810-oil-regeneration-station-type-urm-0-8</link>
   <comments>http://blogs.albawaba.com/ukrbudmash/68207/2008/07/25/91810-oil-regeneration-station-type-urm-0-8</comments>
   <guid>http://blogs.albawaba.com/ukrbudmash/68207/2008/07/25/91810-oil-regeneration-station-type-urm-0-8</guid>
      <dc:creator>ukrbudmash</dc:creator>
      
    <category>General</category>
         <pubDate>Fri, 25 Jul 2008 10:50:07 +0000</pubDate>
   <source url="http://blogs.albawaba.com/feed/rss20/66498">Oil Regeneration</source>
                    </item>
    <item>
   <title>Oil Regeneration Station type URM- 0,2</title>
   <description>
    &lt;p class=&quot;MsoNormal&quot; style=&quot;margin-bottom: 12pt&quot;&gt;&lt;a id=&quot;res_7684&quot; href=&quot;/resserver.php?blogId=66498&amp;amp;resource=7684-oil%20regeneration.jpg&quot;&gt;&lt;img src=&quot;/resserver.php?blogId=66498&amp;amp;resource=7684-oil%20regeneration.jpg&amp;amp;mode=preview&quot; border=&quot;0&quot; /&gt;&lt;/a&gt;&lt;span&gt;Oil Regeneration &amp;amp;
reclamation systems for industrial lubrication oils. Transformer Oil
Regeneration Station type (R) 0,2 is apply to purify and regenerate the
used insulating oils such as power transformer oil, high-voltage switch
oil, mutual inductor oil whose viscosity at temperature 50 C does not
exceed 70 cSt. It removes water, gas, particulate matters, free carbon,
deep oxides. It also removes acidity and vaccuumizes a transformer. The
Station can recover the oil color. After purification, the used
insulating oil can reach international standard and recover its
original function. Oil Regeneration Station is used for mounting,
repairing and operating high-voltage oil equipment with voltage up to
1150 kV (power transformers, high-voltage switches, mutual inductors,
cable and capacitors which have insulation system). The machine
complies with number 4 category placement and climatic design UHL as
per GOST 15 150-69. Capacity, m3/h 0,7 Sorbent consumption, % by oil
weight 4-6 One-time sorbent feeding, kg 50 Oil temperature, 95 Oil
heater power, W 27 Set power consumption, W 37 Three-phase VAC~ 50 Hz,
V 380.&lt;/span&gt;&lt;/p&gt;&lt;p style=&quot;margin-top: 0pt; margin-bottom: 0pt&quot;&gt;&amp;nbsp;&lt;br /&gt;&lt;strong&gt;&lt;span&gt;&lt;span style=&quot;font-size: x-large; font-family: Arial; color: #008000&quot;&gt;UkrBudMash Plant Ltd&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
				&lt;p class=&quot;MsoNormal&quot; style=&quot;margin-top: 0pt; margin-bottom: 0pt&quot;&gt;
				&lt;strong&gt;&lt;span style=&quot;font-family: Arial; color: #000080&quot;&gt;&lt;span&gt;ul. 
				Sadovskogo 8, Poltava, 
				36034 Ukraine&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
				&lt;p class=&quot;MsoNormal&quot; style=&quot;margin-top: 0pt; margin-bottom: 0pt&quot;&gt;
				&lt;strong&gt;&lt;span style=&quot;font-family: Arial; color: #000080&quot;&gt;t&lt;/span&gt;&lt;span style=&quot;font-family: Arial&quot;&gt;&lt;span&gt;&lt;span style=&quot;color: #000080&quot;&gt;el/fax:&lt;/span&gt; &lt;span style=&quot;color: #ff0000&quot;&gt;+38 0532&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family: Arial; color: #ff0000&quot;&gt; 
				66-86-45&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
				&lt;p class=&quot;MsoNormal&quot; style=&quot;margin-top: 0pt; margin-bottom: 0pt&quot;&gt;
				&lt;strong&gt;&lt;span style=&quot;font-family: Arial; color: #000080&quot;&gt;t&lt;/span&gt;&lt;span style=&quot;font-family: Arial&quot;&gt;&lt;span&gt;&lt;span style=&quot;color: #000080&quot;&gt;el/fax:&lt;/span&gt; &lt;span style=&quot;color: #ff0000&quot;&gt;+38 0532&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family: Arial; color: #ff0000&quot;&gt; 
				66-86-17&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
				&lt;p class=&quot;MsoNormal&quot; style=&quot;margin-top: 0pt; margin-bottom: 0pt&quot;&gt;
				&lt;strong&gt;&lt;span style=&quot;font-family: Arial; color: #000080&quot;&gt;t&lt;/span&gt;&lt;span style=&quot;font-family: Arial&quot;&gt;&lt;span&gt;&lt;span style=&quot;color: #000080&quot;&gt;el/fax:&lt;/span&gt; &lt;span style=&quot;color: #ff0000&quot;&gt;+38 0532&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family: Arial; color: #ff0000&quot;&gt; 
				66-86-42&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
				&lt;p style=&quot;margin-top: 0pt; margin-bottom: 0pt&quot;&gt;
		&lt;span style=&quot;font-family: Arial; color: #000080&quot;&gt;
		&lt;a href=&quot;http://www.hydrodynamictechnology.com.ua/&quot;&gt;
		&lt;span&gt;http://www.&lt;/span&gt;&lt;/a&gt;&lt;a href=&quot;mailto:info@ukrbudmash.com.ua&quot;&gt;ukrbudmash.com.ua&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;&lt;p style=&quot;margin-top: 0pt; margin-bottom: 0pt&quot;&gt;
		&lt;span style=&quot;font-family: Arial&quot;&gt;E-mail: &lt;a href=&quot;mailto:alf@ukrbudmash.com.ua&quot;&gt;info@ukrbudmash.com.ua&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;margin-bottom: 12pt&quot;&gt;&amp;nbsp;&lt;/p&gt;
   </description>
   <link>http://blogs.albawaba.com/ukrbudmash/68207/2008/07/24/91703-oil-regeneration-station-type-urm-0-2</link>
   <comments>http://blogs.albawaba.com/ukrbudmash/68207/2008/07/24/91703-oil-regeneration-station-type-urm-0-2</comments>
   <guid>http://blogs.albawaba.com/ukrbudmash/68207/2008/07/24/91703-oil-regeneration-station-type-urm-0-2</guid>
      <dc:creator>ukrbudmash</dc:creator>
      
    <category>General</category>
         <pubDate>Thu, 24 Jul 2008 10:56:57 +0000</pubDate>
   <source url="http://blogs.albawaba.com/feed/rss20/66498">Oil Regeneration</source>
                    </item>
    <item>
   <title>Oil Regeneration System URM-0.7</title>
   <description>
    &lt;p&gt;&lt;a id=&quot;res_7685&quot; href=&quot;/resserver.php?blogId=66498&amp;amp;resource=7685-oil%20regeneration.jpg&quot;&gt;&lt;img src=&quot;/resserver.php?blogId=66498&amp;amp;resource=7685-oil%20regeneration.jpg&amp;amp;mode=preview&quot; border=&quot;0&quot; /&gt;&lt;/a&gt;&lt;span style=&quot;font-size: x-small; font-family: Verdana&quot;&gt;Oil Regeneration System URM-0.7 is one of the rang eof transformer oil regeneration systems proposed. It is designed for regeneration of transformer oil, industrial oil, and turbine oil, with viscosity up to 70 cSt at 50С, removing solids, water and gases from the oils. The oil regeneration plant is used for mounting, repairing and operating of high-voltage oil equipment with voltage up to 1150 kV (power transformers, high-voltage switches etc.)&lt;/span&gt;&lt;/p&gt;&lt;p style=&quot;margin-top: 0pt; margin-bottom: 0pt&quot;&gt;&lt;strong&gt;&lt;span&gt;&lt;span style=&quot;font-size: x-large; font-family: Arial; color: #008000&quot;&gt;UkrBudMash Plant Ltd&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;margin-top: 0pt; margin-bottom: 0pt&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-family: Arial; color: #000080&quot;&gt;&lt;span&gt;ul.  				Sadovskogo 8, Poltava,  				36034 Ukraine&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;margin-top: 0pt; margin-bottom: 0pt&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-family: Arial; color: #000080&quot;&gt;t&lt;/span&gt;&lt;span style=&quot;font-family: Arial&quot;&gt;&lt;span&gt;&lt;span style=&quot;color: #000080&quot;&gt;el/fax:&lt;/span&gt; &lt;span style=&quot;color: #ff0000&quot;&gt;+38 0532&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family: Arial; color: #ff0000&quot;&gt;  				66-86-45&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;margin-top: 0pt; margin-bottom: 0pt&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-family: Arial; color: #000080&quot;&gt;t&lt;/span&gt;&lt;span style=&quot;font-family: Arial&quot;&gt;&lt;span&gt;&lt;span style=&quot;color: #000080&quot;&gt;el/fax:&lt;/span&gt; &lt;span style=&quot;color: #ff0000&quot;&gt;+38 0532&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family: Arial; color: #ff0000&quot;&gt;  				66-86-17&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;&lt;p class=&quot;MsoNormal&quot; style=&quot;margin-top: 0pt; margin-bottom: 0pt&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-family: Arial; color: #000080&quot;&gt;t&lt;/span&gt;&lt;span style=&quot;font-family: Arial&quot;&gt;&lt;span&gt;&lt;span style=&quot;color: #000080&quot;&gt;el/fax:&lt;/span&gt; &lt;span style=&quot;color: #ff0000&quot;&gt;+38 0532&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family: Arial; color: #ff0000&quot;&gt;  				66-86-42&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;&lt;p style=&quot;margin-top: 0pt; margin-bottom: 0pt&quot;&gt;&lt;span style=&quot;font-family: Arial; color: #000080&quot;&gt;&lt;a href=&quot;http://www.hydrodynamictechnology.com.ua/&quot;&gt;&lt;span&gt;http://www.&lt;/span&gt;&lt;/a&gt;&lt;a href=&quot;mailto:info@ukrbudmash.com.ua&quot;&gt;ukrbudmash.com.ua&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;&lt;p style=&quot;margin-top: 0pt; margin-bottom: 0pt&quot;&gt;&lt;span style=&quot;font-family: Arial&quot;&gt;E-mail: &lt;a href=&quot;mailto:alf@ukrbudmash.com.ua&quot;&gt;info@ukrbudmash.com.ua&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;&lt;p&gt;&amp;nbsp;Only 31.300 Euro&lt;/p&gt;
   </description>
   <link>http://blogs.albawaba.com/ukrbudmash/68207/2008/07/24/91702-oil-regeneration-system-urm-0.7</link>
   <comments>http://blogs.albawaba.com/ukrbudmash/68207/2008/07/24/91702-oil-regeneration-system-urm-0.7</comments>
   <guid>http://blogs.albawaba.com/ukrbudmash/68207/2008/07/24/91702-oil-regeneration-system-urm-0.7</guid>
      <dc:creator>ukrbudmash</dc:creator>
      
    <category>General</category>
         <pubDate>Thu, 24 Jul 2008 10:54:27 +0000</pubDate>
   <source url="http://blogs.albawaba.com/feed/rss20/66498">Oil Regeneration</source>
                    </item>
    <item>
   <title>Congratulations!</title>
   <description>
    If you can read this post, it means that the registration process was successful and that you can start blogging
   </description>
   <link>http://blogs.albawaba.com/ukrbudmash/68207/2008/07/15/90511-welcome</link>
   <comments>http://blogs.albawaba.com/ukrbudmash/68207/2008/07/15/90511-welcome</comments>
   <guid>http://blogs.albawaba.com/ukrbudmash/68207/2008/07/15/90511-welcome</guid>
      <dc:creator>ukrbudmash</dc:creator>
      
    <category>General</category>
         <pubDate>Tue, 15 Jul 2008 12:14:42 +0000</pubDate>
   <source url="http://blogs.albawaba.com/feed/rss20/66498">Oil Regeneration</source>
     </item>
   </channel>
</rss>